Excalibur Multirate DAP Installation and Operation
5-48
Line Test Interval
This parameter specifies the duration of the dedicated line test. The possible settings are
5, 10, 15, and 30 minutes.
Answer
This parameter specifies the conditions that cause the DAP to automatically answer dial
line calls. You can select from the following options:
Always - the DAP always answers calls.
Never - automatic answering is disabled.
DDS Line or Local Loop Down - the DAP only answers calls when the DDS
line goes down (due to Out of Service codes, Abnormal Station codes, loss of
multiport framing, or loss of network framing) or when an invalid DDS signal is
received from the network.
No Signal - the DAP only answers calls when an invalid DDS signal is received
from the network.
The DAP constantly monitors the network interface for an off-hook (ringing) state.
When ringing is detected, the DAP automatically answers the call in response to the
selected condition. When the dial backup connection is successfully established, the
DAP displays the message Switched To Dial on the front panel followed by an
audible beep. When automatic answering is disabled or when the selected condition is
not present, the DAP informs the front panel that ringing is detected, but it will not
answer the call.
The options listed above are provided with software revision number SSC0900 or above.
These revisions are compatible with previous revisions. Previous revisions only provide
the settings Enabled and Disabled. If you upgrade a unit with software revision
number SSC0840, you do not have to reconfigure the DAP. The unit will retain its
parameter settings.
You can fully configure the Answer Calls feature from a CMS 400 network management
system equipped with software revision number 4.0 or above. If it is equipped with a
software revision number lower than 4.0, configure this feature by using the WAN
Control, Excalibur Front Panel function. It is necessary to do so because an older CMS
network management system only provides the settings Enabled and Disabled. If
you configure Answer Calls from an older system, depending on the previous settings,
the Disabled selection may select Never (automatic answering is disabled) or DDown
(answer only when the DDS line is down or the local loop signal is lost). The Enabled
selection may select Alwys (always answer calls) or Nosig (answer only when the
local loop signal is lost).