Excalibur Multirate DAP Installation and Operation
3-6
Table 3-2. V.35 DTE Connector, Pin/Signal Assignments
Pin
CCITT V.35
Symbol Mnemonic
Input/
Output Function
B 102 Signal ground
C 105 RTS Input Request-to-Send
D 106 CTS Output Clear-to-Send
E 107 DSR Output Data Set Ready
F 109 RLSD (DCD) Output Received Line Signal Detector
H 108 DTR Input Data Terminal Ready
P 103 TXD (A) Input Transmit Data
S 103 TXD (B) Input Transmit Data
R 104 RXD (A) Output Receive Data
T 104 RXD (B) Output Receive Data
U 113 ExTxC (A) Input External Transmit Clock
W 113 ExTxC (B) Input External Transmit Clock
V 115 RxC (A) Output Receiver Signal Element Timing
X 115 RxC (B) Output Receiver Signal Element Timing
Y 114 TxC (A) Output Transmitter Signal Element Timing
AA 114 TxC (B) Output Transmitter Signal Element Timing
NN 142 TM Output Test Mode
Connecting to the Dedicated Line
The Excalibur Multirate DAP provides an 8-pin modular jack labeled DED for
connecting to the dedicated telephone line. The proper cable to use depends on the type
of dedicated line outlet at your site:
If the dedicated line outlet is an 8-pin modular jack, use Cable Part No. 5956-
149G. This cable has 8-pin plugs at both ends.